Dawnergy Technologies(Shanghai) Co., Ltd.

Help people better connected through fiber

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Outdoor Fiber Optic Cable /

GYTS G652D Outdoor Fiber Optic Cable

Contact Now
Dawnergy Technologies(Shanghai) Co., Ltd.
Visit Website
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MrPeter Bi
Contact Now

GYTS G652D Outdoor Fiber Optic Cable

Ask Latest Price
Video Channel
Brand Name :Dawnergy
Model Number :GYTS-12/24/48/96/144 G652D
Certification :CE/TELCORDIA
Place of Origin :CHINA
MOQ :100KM
Payment Terms :T/T, L/C, D/A, D/P
Supply Ability :10,000KM PER DAY
Delivery Time :10-14 work days
Packaging Details :wooden drum
Brand :Dawnergy
Product :Fiber Optic Cable
Fiber :G652D
Loose tube :PBT
Central strength member :Steel wire
Outer Sheath :HDPE
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

1. Reference

The cable offered are designed, manufactured and tested according to the standards as follows:

IEC 60794-1-1 Optical fibre cables-part 1-1: Generic specification-General
IEC 60794-1-2 Optical fibre cables-part 1-2: Generic specification-Basic optical cable test procedure
IEC 60794-3 Optical fibre cables-part 3: Sectional specification-Outdoor cables

2. Cable Cross-section

GYTS G652D Outdoor Fiber Optic Cable

3. Cable Identification

2.1 Fiber color code

No. 1 2 3 4 5 6
Color Blue Orange Green Brown Gray White
No. 7 8 9 10 11 12
Color Red Black Yellow Violet Pink Aqua

2.2 Loose tube (LT) & filler rod (FR) color code

Fiber count Element no.
1 2 3 4 5 6 7 8 9 10 11 12
12 LT LT FR FR FR
24 LT LT LT LT FR
48 LT LT LT LT FR
96 LT LT LT LT LT LT LT LT
144 LT LT LT LT LT LT LT LT LT LT LT LT

“LT” means “loose tube”;“FR” means “filler rod”

4. Cable Assembly & Dimensions

Item Contents Value
12 24 48 96 144
Loose tube Number 2 4 4 8 12
Outer diameter (mm) 1.9 1.9 2.1 2.1 2.1
Thickness(mm) 0.3
Material PBT
Water blocking Tube filling compound
Filler Material PP
Number 3 1 1 0 0

Max. Fiber counts

per tube

G.652D 6 6 12 12 12
Central strength member Material Steel wire
Diameter (mm) 1.4 1.4 1.6 2.0 2.0
PE layer diameter (mm) - - - 3.6 6.2
Water blocking Material Water blocking yarn & Water blocking tape
Outer Sheath Material HDPE
Color Black
Thickness (mm) 1.7±0.2
Cable diameter(mm) Approx 9.8±0.3 9.8±0.3 10.4±0.3 12.4±0.3 15.0±0.3
Cable weight(kg/km) Approx. 80±5% 84±5% 96±5% 143±5% 199±5%

5. Performance of Cabled Optical Fiber

The performance of cabled optical fiber (ITU-T Rec. G.652D)

Item Specification
Fiber type Single mode
Fiber material Doped silica

Attenuation coefficient

@ 1310 nm

@ 1550 nm

≤ 0.35 dB/km

≤ 0.21 dB/km

Cable cut-off wavelength  ≤1260 nm
Zero-dispersion wavelength 1300 ~ 1324 nm
Zero-dispersion slope ≤ 0.092 ps/(nm2.km)
PMD ≤0.2 ps/km1/2
Mode field diameter @ 1310 nm 8.7~9.5 um
Core / Clad concentricity error ≤ 0.6 um
Cladding diameter 125±1 um
Cladding non-circularity ≤1.0%
Primary coating diameter 250±15 um

6. Performance of Optical Fiber Cable

6.1 Cable bending radius: 10 x cable diameter (static)

20 x cable diameter (dynamic)

6.2 Application temperature range

Operating temperature range : -40oC to +70oC
Storage / Transport temperature range : -40oC to +70oC
Installation temperature range : -40oC to +70oC

6.3 Mechanical & environmental performance test

S/N Item Test Method Acceptance Condition
1 Tensile Strength IEC 794-1-E1

-Load: 1500N

Length of cable under load: 50m

-Load time: ≥1min.

-Loss change≤0.1 dB@1550 nm after test

-Fiber strain≤0.6%

-No fiber break and no sheath damage

2

Crush Test IEC 794-1-E3

- Load:1000N/100 mm

- Load time: ≥1min.

-Loss change≤0.1 dB@1550 nm after test

-No fiber break and no sheath damage

3

Impact test IEC60794-1-21-E4

-Impact hight:1m

-Impact weight:20J

-Points of impact: 3

-Times of per point: 1

-Radius:300mm

-Loss change ≤ 0.1 dB@1550 nm

-No fiber break and no sheath damage

4

Repeated Bending IEC 794-1-E6

  • Bending radius: 20 x cable diameter

-Load:150N

-Flexing rate: 2 sec/cycle

-No. of cycle: 25

-Loss change≤ 0.1 dB @1550 nm

-No fiber break and no sheath damage

5

Torsion

IEC 794-1-E7

-Length: 1m

-Load:150N

-Twist angle: ±90°

-No. of cycle: 10

-Loss change≤0.1 dB @1550 nm

-No fiber break and no sheath damage

6

Water Penetration Test IEC 794-1-F5B

-Height of water: 1m

-Sample length: 3m

-Test time: 24 hours

-No water shall have leaked from the opposite end of cable.

7

Temperature Cycling Test IEC 794-1-F1

-Temperature step:

+20℃→-40℃→+70℃→+20 ℃

-Time per each step: 12hrs

-Number of cycle: 2

-Loss change≤ 0.05dB @1550 nm

-No fiber break and no sheath damage

-No sheath damage

8

Compound Flow IEC 794-1-E14

-Sample length: 30cm

-Temp: 70°C± 2°C

-Time: 24 hours

- No compound flow

7. Packing

7.1 Each single cable length been wound on an iron wooden drum.

7.2 Standard drum length is 4000m ±2% or customer order

7.3 Covered by plastic buffer sheet.

7.4 Sealed by strong wooden battens.

7.5 At least 3m of cable inner end should be reserved for testing.

GYTS G652D Outdoor Fiber Optic Cable

Note : The value “D” contain the seal dimension.

Inquiry Cart 0